 Universal Transmitter with HART EDDL/DTM  XNX-RMSE-NHNNN CO CO2 H2 H2S cl2 and LEL gas detector

Universal Transmitter with HART EDDL/DTM XNX-RMSE-NHNNN CO CO2 H2 H2S cl2 and LEL gas detector

  • Overview
  • Related Products
Product Description
     XNX is an extremely flexible transmitter that can be configured to accept an
input from any of the gas sensor technologies. It can also be configured to provide
a wide variety of industry standard output signals.This enables users to have a single
type of interface to all their gas detection needs, even when different types of
detectors are employed,to most effectively address the different gas detection
applications on site.
    The most effective gas detection systems often employ a variety of detection
technologies including point flammable detectors (both catalytic and infrared type),
toxic and Oxygen electrochemical cell type detectors and open path infrared detectors.
XNX provides a common transmitter interface to all of these and can be configured to
provide industry standard signal outputs to match the individual requirement of each
application or the preferred site standard. If site output standards change, XNX can
be reconfigured to provide the new required output. XNX has also been future proofed
by having the ability to have other output modules fitted as new output standards are
developed and adopted by industry. 
     Having a common transmitter platform for all your gas detectors brings further
benefits.Common tools and installation methods simplifies and reduces cost of
installation. The common user interface makes operation faster to learn and easier
to navigate, thus reducing time needed for training as well as reducing the chance
of incorrectly interpreting messages or incorrectly changing settings. Common spare
parts also mean reduced maintenance spares stock levels and cost for all detectors.
XNX allows you to apply the most appropriate gas detection technologies for each
application, standardise the interface to those detectors and has the flexibility to provide
the required signal outputs. With XNX the answer is always yes.
dtm xnx rmse nhnnn co co2 h2 h2s cl2 and lel gas detector-1
Product Description

Category

Details

XXN Transmitter

 

Use

High specification universal transmitter for use with a wide range of Honeywell Analytics local or remote gas detectors for the detection of flammable, toxic and Oxygen gas hazards. Suitable for use in Zone 1 and 2 and Zone 21 and 22 hazardous areas, and North American Class I and II Division 1 or 2 areas.

Construction

 

Material

Housing: 5 - minute field - painted aluminium alloy or 316 stainless steel

Weight (Approx.)

Aluminium alloy: 2.8kg (6.2lb); 316 stainless steel: 5kg (11lb)

Mounting

Surface mount via integral mounting lugs. Optional pipe mounting kit suitable for 100mm to 150mm (4" to 6") pipe. Optional ceiling mounting bracket

Entries

5 configurable entries: 2 x 3/4" NPT bottom entry M25 for ATEX/IECEx versions or 3/4" NPT for UL/CSA certified versions

Dimensions

160mm x 197mm x 114mm (6.3" x 7.8" x 4.5")

Environmental

 

IP Rating

IP66 in accordance with EN60529; NEMA 4X

Operating Temperature

- 40°C to + 65°C (- 40°F to + 149°F)

Operating Humidity

0 - 99%RH non - condensing

Operating Pressure

90 - 110kPa

Storage Conditions

- 40°C to + 70°C (- 40°F to 158°F); 0 - 99% non - condensing

Electrical

 

Input Voltage Range

EC and mV versions: 16 to 30Vdc; R version: 18 to 32Vdc (24Vdc nominal)

Max Power Consumption

XXN (EC): Catalytic: 6.2 wattsXXN (mV): Catalytic or IR: 6.5 wattsXXN R with Searchpoint Optima Plus: 9.7 wattsXXN with Searchline Excel Receiver: 13.2 watts

Current Output

Fully configurable isolated 4 - 20mA & HART® output; multiple current output sink, current source and isolated modes of operation (supports HART® 6.0 protocol)

4 - 20mA Signal Output settings

30.00 ± 0.15mA: Fault4.0 mA: Minimum range20.0 mA: Full scale2.0 mA to 4.0 mA (2.0mA - 17mA): Normal gas measurementThe full scale range for Inhibit, Warning, Beam Blocked and Low Signal is 1 to 4mA. For an over range condition, the range is 20 to 22mA

4 - 20mA Signal Accuracy

± 1% of the scale output

Functions Supported by HART®

Gas readingGas name and units of measurement4 - 20mA signal levelGeneral/Analytical InformationInstallationTroubleshootingForcing of 4 - 20mA outputDetailed sensor information including:Optical transmitter signal levelDynamic reserve (Searchline Excel only)Raw reading24V supply voltageTemperatureCalibration and configuration statusDetailed fault and warning informationFault and alarm historyZero calibration

Terminals

Cap - style pluggable with retaining screws for wire diameter 0.5mm² to 2.5mm² (approx. 20AWG to 14AWG)

Certification

 

European

ATEX: Ⅱ(2)G [ia] ⅡC Ex nA ⅡC T4/T6 Gb; Ⅱ(2)D [ib] ⅡIC T85/T150 Db

International

IECEx: Ⅱ(2)G [ia] ⅡC Ex nA ⅡC T4/T6 Gb; Ⅱ(2)D [ib] ⅡIC T85/T150 Db

North American

UL: Class I, Div 1, Groups B, C, and D; Class 1, Div 1, Groups F & G / Class I, Zone 1 Groups IB + H2; Class II, Zone 20 & 21FM: AEx [ia] ⅡC [ib] ⅡC + 12 to + 40°C; T5 and ≤ 85°C

Canadian

CSA: Class I, Div 1, Groups B, C, and D; Class 1, Div 1, Groups F & G / Class I, Zone 1 Groups IB + H2

EMC

EN60728 - 1:2006; EN61000 - 4 - 2:2007

Performance

Europe – ATEX, EN50454, EN50140, EN50270:2010, EN51398, EN60706 - 39 - 1North America – UL 913; UL 1203; CSA 22.2 No. 152IEC61508 (SIL Assessment, SIL 2, ECEx ZD 005

Local HART® Port (Optional)

 

Description

Provides externally accessible connections to the XXN transmitter to enable “hot” connection of HCF275/HART® or equivalent hand - held configurator

Installation

Fitted to one of the cable entries on the XXN transmitter. Option can be factory fitted or in the field by a qualified service engineer

Environmental Protection

IP66 protected by cover to EN60529 when not in use

Relay Module (Optional)

 

Description

Provides three fully configurable relay outputs that can be activated based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault. Manually resettable latching and non - latching (non - latching “options”)

Rating

Maximum 24VAC/24VDC, 5A total in display module; 5A (10mA per inductive load)

Installation

Option can be factory fitted or display module or in the field by a qualified service engineer