SIZE |
Diffusion: 5.6" x 2.2" x 1.5" W(140.8mm x 57.2mm x 42mm)Pumped: 5.7" x 3.2" x 1.7" D(145mm x 82mm x 42mm) |
WEIGHT |
Diffusion: 12.9 oz (365 g) with Li-Ion battery and cap)Pumped: 14.5 oz (410 g) with Li-Ion battery, cap, and external filter |
SENSORS |
Li - Ion battery - replaceable sensor(s):• Up to four field - replaceable sensors• Oxygen: Galvanic or Electrochemical• Toxic: Electrochemical for H₂S, CO, SO₂, HCN• Rechargeable Li - Ion battery |
BATTERY |
14 hours continuous non - wireless, diffusion11 hours continuous wireless, diffusion10 hours continuous non - wireless, pumped8 hours continuous wireless, pumpedNote: All battery specifications at 86°F (20°C); lower temperatures and alarm conditions will affect battery life. |
RUNNING TIME |
Monochrome graphic display (128 x 60)Display size: 1.57" x 1.06" H (40 x 27mm) with backlightingAutostart or on - demand screen rotation |
DISPLAY GRAPHIC |
Two - button operation |
KEYPAD |
Real - time reading of gas concentrationsBattery statusPump status (if equipped with pump)Wireless statusSTEL, TWA, peak, and minimum valuesMan - Down 95dB buzzer (18.7/30 m typical), vibration alarm, and flashing red LED on - screen indication of alarm conditions |
DIRECT READOUT |
Alarms: Latched, and latching or manual overrideAdditional diagnostic information: Low batteryPump status (if pumped version) and display messageMan - Down Alarm with pre - alarm and real - time remote wireless notification |
DATALOGGING |
Continuous datalogging (3 months for 4 sensors at 1 - minute intervals, 24/7)User - configurable datalogging intervals (from 1 to 3600 seconds)Data download and instrument set - up via upgrades on PC via Travel ChargeReal - time data and status transmission via built - in RF modem (optional) |
DATALOGGING |
Meets RISE Systems Dedicated Wireless Network |
COMMUNICATION AND DATA DOWNLOAD |
Near RISE fame band: 868MHz or 900MHzFCC Part 15, CE ETSI, ANZ |
WIRELESS NETWORK |
Probe: Vault L.O.S: 650 ft (200 m)Probe Guardian and RISE Link Master: L.O.S: 650 ft (200 m)Probe Guardian and RISE Weak Riser: L.O.S: 330 ft (100 m) |
WIRELESS FREQUENCY AND APPROVALS |
EMI and ESD test: 100V/m High to 30V/m, no alarmConduct: ±3V |
WIRELESS RANGE (TYPICAL) |
Pumped: IP - 65Diffusion: IP - 67 |
EM IMMUNITY |
Two - point calibration for zero and span (manual or automatic with AutoRAE 2) |
IP RATING |
Two - point calibration for zero and span (manual or automatic with AutoRAE 2) |
CALIBRATION |
Two - point calibration for zero and span (manual or automatic with AutoRAE 2) |
INSTRUMENT SPECIFICATIONS |
Built-in pump or diffusion |
SAMPLING PUMP |
Can sample through tubing up to 98ft (30m) |
HAZARDOUS AREA |
US and Canada: Class I, Div 1, Groups A,B,C,D and E; Class I, Zone 1, Groups IIC and IIB; Class II, Div 1, Groups F,G; Class III, Div 1Europe: Groups IIA, IIB, IIC T4ATEX/IECEx (TITAN EX only): II 1G Ex ia IIC T4 Ga; II 1D Ex ia IIIC T135°C Da |
TEMPERATURE |
-4°F to 122°F (-20°C to 50°C) for non-condensing temperature |
HUMIDITY |
0% to 95% relative humidity (non-condensing) |
ATTACHMENTS |
Stainless-steel alligator clip or Swivel belt clip (optional) |
LANGUAGES |
Arabic, Chinese, Czech, Dutch, English, French, Indonesian, Polish, Portuguese, Korean, Norwegian, Persian, Russian, Spanish, and Swedish (Language must be changed through ProRAE Studio II) |
WARRANTY |
2-year warranty on device3-year warranty on O₂, LEL, CO, H₂S sensors*1-year warranty on SO₂, HCN sensors* |
|
Specifications are subject to change. |
DEFAULT SENSOR SPECIFICATIONS |
|
GAS MONITOR |
Range |
OXYGEN (O₂) |
0 to 30.0% |
COMBUSTIBLE (LEL) |
0 to 100% LEL |
CARBON MONOXIDE (CO) |
0 to 500 ppm |
HYDROGEN SULFIDE (H₂S) |
0 to 100 ppm |
SULFUR DIOXIDE (SO₂) |
0 to 20 ppm |
HYDROGEN CYANIDE (HCN) |
0 to 50 ppm |
AMMONIA (NH₃) |
100 ppm |
PHOSPHINE (PH₃) |
20 ppm |
CHLORINE (CL₂) |
0 to 50 ppm |
NITROGEN DIOXIDE (NO₂) |
0 to 50 ppm |