portable composite gas analyzer can be used in: accurate detection and analysis of a variety of gas concentration and measurement of environmental temperature and humidity. adopted 3.5-inch high-definition color screen for real-time display, the main detection principles include: electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, and so on. Adopted Swiss high-precision capacitive digital temperature andhumidity sensors. Advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the softwareworks, external appearance, and so on. is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity ofthe gas leakage and various high concentration single gase with the background gas as nitrogen gas or oxygen gas. The types for detection are more than 500 types.
Features and benefits:
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
|
Technical parameters
Gases to be |
Arbitrary combination ofl~6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. |
||||
Application |
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical,pharmaceutical,environmental protection, combustion gas distribution, warehousing,smoke gas analysis, air governance, and so on. |
||||
Detection range |
0~1,10,100,1000,5000,50000,100000ppm,200 mg/L,100%LEL,20%,50%,100%Vol,can be selected; and other ranges can be customized |
||||
Resolution |
0.01ppm or 0.001ppm(0~10 ppm);0.01ppm(0~100 ppm),0.1ppm(0~1000 ppm),lppm(0~10000 ppm or more),0.01 mg/l(0~200 mg/l),0.1%LEL,0.01%,0.001% Vol |
||||
Detection |
Electrochemical, catalytic combustion, infrared, thermal conductivity,PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. |
||||
Sensor service life |
Electrochemical principle:2~3 years;Oxygen gas:2 years or 6 years can be selected; infrared principle:5~10 years; catalytic combustion:3years; thermal conductivity:5 years;PID photoionization:2~3 years. |
||||
Allowable error |
≤±2% F.S(other or higher precision levels can be customized) |
||||
Linearity |
≤±2% |
Linearity |
≤±2% |
Linearity |
≤±2% |
Response time |
T90≤20 seconds |
Recovery time |
≤30 seconds |
||
Working |
Temperature:-40℃~+70 ℃,humidity:≤10~95% RH,and built-in filters can be used in high humidity or high dust environment. |
||||
Sample gas |
-40℃~+70 ℃,and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the maximum temperature of 1300 ℃ |
||||
Temperature |
Optional configuration: temperature at-40℃~+70℃,accuracy level at 0.5 ℃;humidity at 0~100%RH,precision levelat 3%RH |
||||
Power supply |
3.7VDC,5400mAh×2 high capacity rechargeable polymer battery |
||||
Display mode |
3.5-inch high-definition color screen |
||||
Detection mode |
Built-in pump-suction type measurement, and flow rate at 800 ml/min.Calibration flow rate should be greater than 800 ml/min,three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass |
||||
Alarm mode |
It is possible to set as sound & light alarm, turning off the alarm. |
||||
Communication |
USB(charging and communication),communication, automatic recognition |
||||
Data storage |
Standard configuration is the data storage capacity for 100,000 entries;SD card storage and USB disk storage functions are optional configuration |
||||
Protection level |
IP66 |
||||
Explosion-proof |
Intrinsically safe type |
||||
Explosion-proof |
Ex ia IC T4 Ga |
||||
Exterior |
255×210×125mm(L×H×W) |
||||
Weight |
2.5Kg |
||||
Standard |
Manual, qualification certificate, warranty card, USB charger(including the data cable), high-grade aluminum instrument case, built-in humidity dust filter,0.4 meter stainless steel sampling handle(1 meter of hose, with dust filter, not retractable), |
||||
Optional items |
Temperature and humidity measurement function, 1.2 m retractable sampling handle(1-10 meter hose, and the standard length is l meter),external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, CD-ROM |
Part of gases specifications are as following:
Gases |
Range |
accuracy |
response time |
Principle |
|
oxygen (O2) |
0-30%/100%VOL |
<±3%(F.S) |
0.1%VOL |
<15s |
EC |
combustible gas (Ex) |
0-100%LEL |
<±3%(F.S) |
0.1%LEL |
<10s |
Catalytic Oxidation |
0-100%LEL/VOL |
<±3%(F.S) |
0.1%LEL/VOL |
<10s |
NDIR |
|
carbon oxide (CO) |
0—1000/2000ppm |
<±3%(F.S) |
0.1ppm |
<25s |
EC |
hydrogen sulfide (H2S) |
0-100/2000ppm |
<±3%(F.S) |
0.1/1ppm |
<30s |
EC |
sulfur dioxide (SO2) |
0-100ppm |
<±3%(F.S) |
0.1ppm |
<30s |
EC |
Nitric Oxide (NO) |
0-250ppm |
<±3%(F.S) |
1ppm |
<30s |
EC |
nitrogen dioxide (NO2) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
Chlorine (Cl2) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<30s |
EC |
Ammonia (NH3) |
0-100ppm |
<±3%(F.S) |
0.1/1ppm |
<50s |
EC |
hydrogen (H2) |
0-1000ppm |
<±3%(F.S) |
1ppm |
<60s |
EC |
hydrogen cyanide(HCN) |
0-50ppm |
<±3%(F.S) |
0.1ppm |
<100s |
EC |
hydrogen chloride (HCl) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
hydrogen phosphide(PH3) |
0-20ppm/1000ppm |
<±3%(F.S) |
0. 1ppm |
<25s |
EC |
Ozone (O3) |
0-20ppm |
<±3%(F.S) |
0.01ppm |
<30s |
EC |
chlorine dioxide (ClO2) |
0-20ppm |
<±3%(F.S) |
0.1ppm |
<30s |
EC |
ethylene oxide (C2H4O,ETO) |
0-100ppm |
<±3%(F.S) |
0.1ppm |
<45s |
EC |
Formaldehyde (CH2O) |
0-20ppm |
<±3%(F.S) |
0.01ppm |
<30s |
EC |
silane(SiH4 ) |
0-50ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
hydrogen fluoride (HF) |
0-10ppm |
<±3%(F.S) |
0.1ppm |
<60s |
EC |
fluorine (F2 ) |
0-1ppm |
<±3%(F.S) |
0.01ppm |
<60s |
EC |
Phosgene (COCl2 ) |
0-1ppm |
<±3%(F.S) |
0.01ppm |
<60s |
EC |
Total Volatile Organic Compound gases ( TVOC ) |
0-10/100/2000ppm |
<±2%(F.S) |
0.01/0.01/0.1ppm |
<30s |
EC |
Total Volatile Organic Compound gases ( TVOC ) |
0-10/100/2000ppm |
<±2%(F.S) |
0.01/0.01/0.1ppm |
<30s |
PID |
Ningxia Maiya has created a state-of-the-art Portable Pumping Multi-Gas Detector that detects various gases and environmental pollutants. The device has been customized to detect gases like EX, O2, H2S, CO, CO2, CH4, C2H4, as well as VOCS, PM, and O3 environmental sensor.
Features a design is compact making it simple and simple to use in a variety of settings. Designed with a casing is heavy-duty the device is durable and certainly will withstand harsh surroundings, which makes it ideal for used in demanding companies like coal and oil, mining, firefighting, and wastewater treatment flowers.
Has the ability to identify numerous gases and ecological pollutants, ensuring security is complete workers employed in possibly dangerous circumstances. The gas detector is fitted having a high-precision sensor that delivers accurate and data that are reliable real-time.
Manufactured by Ningxia Maiya is user-friendly, and its particular comprehensive display provides immediate readings for all your detected gases. Furthermore, the device comes with a security alarm that alerts users whenever gases which are hazardous detected. The alarms are custom made to suit various settings, making it a device is versatile can be used across multiple applications.
It's settings that are customizable. Users can configure the unit for their needs that are specific rendering it well suited for use within different surroundings. The device has alarm is adjustable and production stations for data recording, making certain users receive real-time information relevant to their specific applications.
Environmental security is crucial, this helps to ensures that personnel work with an environment is safe. The unit ensures that users are alerted of any possible hazards in real-time by detecting an array of gases and ecological pollutants.
Ningxia Maiya Portable Pumping Multi-Gas Detector has an excellent reputation for producing high-quality products, ensuring that customers receive values for their investments.